SUMMARY OF THE SOFTWARE HOUSE FINDINGS FOR THE SOURCE CODE OF THE DRAEGER ALCOTEST 7110 MKIII-C
Important information for private investigators concerning the Alcotest 7110 MKIII-CBase One Technologies, Inc. in New Jersey. Also check out the Base One findings and the Code Review.
In a report released August 28, 2007, Base One determined:
As a matter of public safety, the Alcotest should be suspended from use until the software has been reviewed against an acceptable set of software development standards, and recoded and tested if necessary. An incorrect breath test could lead to accidents and possible loss of life, because the device might not detect a person who is under the influence, and that person would be allowed to drive. The possibility also exists that a person not under the influence could be wrongly accused and/or convicted.
Here is just one bullet point from the link...
1. The Alcotest Software Would Not Pass U.S. Industry Standards for Software Development and Testing: The program presented shows ample evidence of incomplete design, incomplete verification of design, and incomplete “white box” and “black box” testing. Therefore the software has to be considered unreliable and untested, and in several cases it does not meet stated requirements. The planning and documentation of the design is haphazard. Sections of the original code and modified code show evidence of using an experimental approach to coding, or use what is best described as the “trial and error” method. Several sections are marked as “temporary, for now”. Other sections were added to existing modules or inserted in a code stream, leading to a patchwork design and coding style.
Link: http://www.dwi.com/new-jersey/state-v-chun/?yeah